800.406.7387
metalsales.us.com
Pro-Panel II
Metal Sales Manufacturing Corporation
Choose from PVDF, MS Colorfast45Choose from PVDF, MS Colorfast45
®®
or Acrylic Coated Galvalume or Acrylic Coated Galvalume
®®
Available in a wide variety of ENERGY STARAvailable in a wide variety of ENERGY STAR
®®
listed colors listed colors
Applies over solid substrate or open framingApplies over solid substrate or open framing
29 gauge and 26 gauge standard29 gauge and 26 gauge standard
Minimum roof slope 3:12Minimum roof slope 3:12
Metal Roof, Wall and Liner Panel
Anchorage, AK: 866.640.7663
Bay City, MI: 888.777.7640
Deer Lake, PA: 800.544.2577
Denver, CO: 800.289.7663
Detroit Lakes, MN: 888.594.1394
Fontana, CA: 800.782.7953
Fort Smith, AR: 877.452.3915
Independence, MO: 800.747.0012
Jacksonville, FL: 800.394.4419
Jefferson, OH: 800.321.5833
Mocksville, NC: 800.228.6119
Nashville, TN: 800.251.8508
Rock Island, IL: 800.747.1206
Rogers, MN: 800.328.9316
Seattle, WA: 800.431.3470
Sellersburg, IN: 800.999.7777
Sioux Falls, SD: 888.299.0024
Spokane, WA: 800.572.6565
Temple, TX: 800.543.4415
Woodland, CA: 800.759.6019
www.metalsales.us.com
1102 ©MS/07-2019
PRO-PANEL II
®
metalsales.us.comMetal Sales Manufacturing Corporation
Pro-Panel
II Screw Fastener Recommendations
Classic Rib Screw Fastener Recommendations
Classic Rib Nailing Recommendations
Delta Rib Screw Fastener Recommendations
Delta Rib Nailing Recommendations
2-1/2 Corrugated Screw Fastener Recommendations
2-1/2 Corrugated Nailing Fastener Recommendations
Bi-Rib Screw Fastener Recommendations
Bi-Rib Nailing Recommendations
1-1/4 Corrugated Screw Fastener Recommendations
1-1/4 Corrugated Nailing Fastener Recommendations
5V Crimp Nailing Fastener Recommendations
5V Crimp Screw Fastener Recommendations
w
UL 790 Class A Fire Resistance Rating
w
UL 2218, Class 4 Impact Resistance
w
ASTM E 455 Diaphragm Test
w
2017 Florida Building Code Approved:
–29 ga. over 1/2” Plywood 14645.14
36″ panel coverage
Gauges: 29 ga. and 26 ga.
Minimum roof slope: 3:12
Up to a 45 year paint warranty and up to a 10 year edge
corrosion warranty available
Finishes: MS Colorfast45
®
and Acrylic Coated Galvalume
®
Standard Profile
Optional Profile
(Anchorage, AK, Seattle, WA and Spokane, WA branches only)
General InformatIon
Substructure: Pro-Panel II is designed to be utilized over open
structural framing or a solid substrate. To avoid panel distortion,
use a properly aligned and uniform substructure.
Length: Minimum factory cut length is 5-0. Maximum
recommended panel length is 45-0. Longer panels require
additional considerations in packaging, shipping and erection.
Please consult Metal Sales for recommendations.
Fasteners: The fastener selection guide should be consulted
for choosing the proper fastener for specific applications. Quantity
and type of fastener must meet necessary loading and code
requirements.
load table
For all specific warranty, application, installation, and technical information regarding these products,
contact your representative.
SECTION PROPERTIES
ALLOWABLE UNIFORM LIVE LOADS psf (3 or More Equal Spans)
Ga.
Width
(in.)
Yield
ksi
Weight
psf
Top in Compression Bottom in Compression
Inward Load Outward Load
Ixx
in
4
/ft
Sxx
in
3
/ft
Ixx
in
4
/ft
Sxx
in
3
/ft
2’ 2.5’ 3’ 3.5’ 4’ 2’ 2.5’ 3 3.5’ 4’
29 36 80 0.62 0.0060 0.0123 0.0043 0.0128 88 57 40 27 18 85 55 38 27 18
26 36 80 0.79 0.0083 0.0171 0.0057 0.0165 114 73 51 34 23 118 76 53 34 23
Pro-Panel
II Screw Fastener Recommendations
Classic Rib Screw Fastener Recommendations
Classic Rib Nailing Recommendations
Delta Rib Screw Fastener Recommendations
Delta Rib Nailing Recommendations
2-1/2 Corrugated Screw Fastener Recommendations
2-1/2 Corrugated Nailing Fastener Recommendations
Bi-Rib Screw Fastener Recommendations
Bi-Rib Nailing Recommendations
1-1/4 Corrugated Screw Fastener Recommendations
1-1/4 Corrugated Nailing Fastener Recommendations
5V Crimp Nailing Fastener Recommendations
5V Crimp Screw Fastener Recommendations
fastenInG Patterns
ProfIle
testInG
Panel InformatIon
36" Coverage
5/8"
9"
Optional
Profile*
*Anchorage, AK, Seattle, WA and Spokane, WA branches only
Color Side
1. Theoretical section properties have been calculated per AISI 2012 “Specifications for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are effective section
properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2012 specifications considering bending, shear, combined bending and shear and deflection. Allowable load considers the 3
or more equal span condition. Allowable load does not address web crippling, fasteners/support connection or load testing. Panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase in uplift.
5. Diaphragm Capacity - 306 plf average Ultimate Shear Strength using the above fastening pattern on 2x supports located 2' on center per ASTM E 455.